1.
Medisan ; 26(6)dic. 2022. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1440548

ABSTRACT

Introducción: Entre las diferentes complicaciones que surgen en el periodo posoperatorio inmediato, el bajo gasto cardíaco presenta mayor morbilidad y mortalidad asociadas, con una incidencia de hasta 45,0 %. Objetivo: Determinar los factores relacionados con la aparición posoperatoria del bajo gasto cardíaco en pacientes con tratamiento quirúrgico cardiovascular y circulación extracorpórea, según variables demográficas, clínicas y ecocardiográficas. Métodos: Se realizó una investigación analítica, de casos y controles, la cual incluyó a pacientes que recibieron tratamiento quirúrgico cardíaco en el Servicio de Cardiología y Cirugía Cardiovascular del Hospital Provincial Clinicoquirúrgico Docente Saturnino Lora de Santiago de Cuba, desde enero hasta diciembre de 2019. Cada grupo de estudio estuvo conformado por 43 integrantes, para lo cual se consideró la presencia del síndrome de bajo gasto cardíaco (casos) o no (controles). Resultados: En la serie predominaron los pacientes menores de 65 años de edad en ambos grupos de estudio (51,2 y 73,5 % para casos y controles, respectivamente), así como el sexo masculino (60,9 %); de igual modo, resultó más frecuente la intervención quirúrgica de emergencia (80,2 %). La fibrilación auricular y la función sistólica del ventrículo derecho presentaron alta significación estadística (p<0,05). Conclusiones: Algunos elementos clínicos y ecocardiográficos (edad, fibrilación auricular, función sistólica de los ventrículos izquierdo y derecho, así como intervención quirúrgica de emergencia) se asociaron de manera independiente a la aparición del bajo gasto cardíaco.


Introduction: Among the different complications that arise in the immediate postoperative period, the low cardiac output presents higher associated morbidity and mortality, with an incidence of up to 45.0 %. Objective: To determine the factors related to the postoperative emergence of the low cardiac output in patients with cardiovascular surgical treatment and extracorporeal circulation, according to demographic, clinical and echocardiographic variables. Methods: An analytic, cases and controls investigation was carried out, which included patients that received heart surgical treatment in the Cardiology and Cardiovascular Surgery Service of Saturnino Lora Teaching Clinical Surgical Provincial Hospital in Santiago de Cuba, from January to December, 2019. Each study group was conformed by 43 members, for which was considered the presence (cases) or not (controls) of the low cardiac output syndrome. Results: In the series there was a prevalence of the patients under 65 years in both study groups (51.2 and 73.5 % for cases and controls, respectively), as well as the male sex (60.9 %); in a same way, the emergency surgical intervention was the most frequent (80.2 %). The atrial fibrillation and the systolic function of the right ventricle presented high statistical significance (p <0.05). Conclusions: Some clinical and echocardiographic elements (age, atrial fibrillation, systolic function of the left and right ventricles, as well as emergency surgical intervention) were associated in an independent way with the emergence of the low cardiac output.


Subject(s)
Cardiac Output, Low , Ventricular Dysfunction , Thoracic Surgery , Extracorporeal Circulation
2.
Rev. chil. cardiol ; 41(2): 100-104, ago. 2022. ilus
Article in Spanish | LILACS | ID: biblio-1407755

ABSTRACT

Resumen: La oxigenación por membrana extracorpórea (ECMO) es de gran utilidad al proveer soporte ventilatorio a pacientes con hipoxia, pero su utilidad en el manejo de pacientes con obstrucción central de la vía aérea y riesgo vital no ha sido frecuentemente usada. La broncoscopía intervencional como terapia bajo ventilación convencional es de alto riesgo en este tipo de pacientes, pero es posible lograr excelentes resultados al ser asociada a ECMO. Comunicamos el caso clínico de 2 pacientes que presentaban disnea en reposo y falla ven1ila1oria aguda ca1as1rófica debido a una obstrucción casi total del lumen traqueal, de causa tumoral. En ambos pacientes en forma urgente se inició soporte circulatorio mediante ECMO VV, mientras se efectuaba la resección tumoral broncoscópica. Luego de terminada la cirugía traqueal, en ambos pacientes se retiró el soporte, siendo decanulados sin eventos y con una buena evolución clínica posterior. Se discute el beneficio del soporte ECMO en este tipo de pacientes.


Abstract: In patients with severe central airway stenosis bronchoscopy-guided intervention therapy under conventional ventilation conveys a high risk. Extracorporeal membrane oxygenation (ECMO) provides very good cardiopulmonary support, but is rarely used in bronchoscopy-guided interventional therapy. We report 2 patients with resting dyspnea due to severe tumor tracheal obstruction and acute pulmonary failure with imminent vital risk. Both patients were cannulated and the ECMO circuit installed on a nearly emergency basis. Tumors were excised, and the patients weaned from cardiopulmonary bypass uneventfully. Subsequent clinical course was satisfactory in both cases. A brief discussion of this condition is included.


Subject(s)
Humans , Aged , Extracorporeal Membrane Oxygenation/methods , Ventilation/methods , Airway Obstruction/surgery , Extracorporeal Circulation/methods
3.
Chinese Journal of Medical Instrumentation ; (6): 164-167, 2022.
Article in Chinese | WPRIM | ID: wpr-928880

ABSTRACT

Aiming at the current situation of performance testing of hemodialysis extracorporeal circulation tubing, which has slow efficiency, inaccurate measurement, and inconvenient testing, a portable detection system for testing the performance of hemodialysis extracorporeal circulation tubing is designed. The system mainly includes a hardware system and a software system. The hardware system uses STM32F407 single-chip microcomputer as the core to design the driving control of the roller pump; the software system uses the C++ real-time operating system, and the flow detection data is transmitted to the upper computer through RS485 communication and displayed. Experimental showed that the system detects the accuracy and the stability of the flow rate. It has the characteristics of stability and high precision. The relative error of the experimental measurement is within the range of ±10%. The weight of the whole machine is 2 kg, which improves the efficiency by 50% compared with the traditional detection method.


Subject(s)
Computers , Equipment Design , Extracorporeal Circulation , Microcomputers , Renal Dialysis , Software
4.
Rev. colomb. anestesiol ; 49(4): e502, Oct.-Dec. 2021. graf
Article in English | LILACS, COLNAL | ID: biblio-1341247

ABSTRACT

Abstract Airway-related pathology poses a significant challenge to the pediatric anesthesiologist. This case report involves a 28-day-old neonate diagnosed with congenital tracheal stenosis who underwent a slide tracheoplasty intervention with extracorporeal circulation. The anesthetic management is described, together with our experience in the face of a challenging situation, including adverse events during surgery.


Resumen La patología relacionada con la vía aérea es uno de los grandes retos a los que se enfrenta un anestesiólogo pediátrico. En este reporte de caso se presenta una cirugía realizada en nuestro hospital. Un neonato de 28 días de vida, diagnosticado con estenosis traqueal congénita fue intervenido con traqueoplastia por deslizamiento, bajo soporte con circulación extracorpórea. Se documenta el manejo anestésico, y la experiencia de enfrentar un reto complejo, incluyendo los eventos adversos que ocurrieron durante la cirugía.


Subject(s)
Humans , Male , Female , Infant, Newborn , Airway Remodeling , Congenital Abnormalities , Thoracic Surgery , Trachea , Infant, Newborn , Extracorporeal Circulation
5.
Int. j. cardiovasc. sci. (Impr.) ; 34(5): 499-505, Sept.-Oct. 2021. tab, graf
Article in English | LILACS | ID: biblio-1340057

ABSTRACT

Abstract Background: The indiscriminate use of blood transfusion in surgery has been associated with increased risk of infection and increased length of hospital stay. Objective: To identify the average amount of bleeding and rates of transfusion of blood products in the postoperative period of patients undergoing cardiac surgery in a cardiology center. Methods: Medical records of patients who underwent myocardial revascularization surgery and/or heart valve replacement with use of cardiopulmonary bypass (CPB) were analyzed. Perioperative data such as CPB time, hematocrit and hemoglobin values were collected after surgery. The amount of bleeding (mL), blood transfusion (IU), clinical complications and time of hospitalization were also recorded. The correlation between bleeding in the postoperative period and blood transfusion was performed using the Spearman correlation. A p < 0.05 was considered statistically significant. Results: A total of 423 patients undergoing coronary artery bypass grafting (51.5%) or heart valve replacement (33.6%) were included. During the first 24 hours, the average bleeding volume was 353.3 ± 268.3 mL. Transfusion of blood products was required in 40.1% of cases, most frequently (70.6%) in the immediate postoperative period. Red blood cell concentrate was the most frequently used product (22.9% and 60%). Conclusion: The occurrence of bleeding in the cases was low, and when transfusion of blood components was indicated, red blood cell concentrates were the most widely used component. (Int J Cardiovasc Sci. 2021; [online].ahead print, PP.0-0)


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Postoperative Care/methods , Blood Transfusion/methods , Transcatheter Aortic Valve Replacement/methods , Myocardial Revascularization/methods , Retrospective Studies , Extracorporeal Circulation , Transfusion Reaction/complications , Hemorrhage , Length of Stay
6.
Rev. bras. ter. intensiva ; 33(3): 469-476, jul.-set. 2021. graf
Article in English, Portuguese | LILACS | ID: biblio-1347303

ABSTRACT

RESUMO Desde a instituição da circulação extracorpórea, há cinco décadas, a lesão cerebral decorrente desse procedimento durante cirurgias cardiovasculares tem sido uma complicação frequente. Não existe uma causa única de lesão cerebral pelo uso de circulação extracorpórea, porém se sabe que acomete cerca de 70% dos pacientes submetidos a esse procedimento. A avaliação da pressão intracraniana é um dos métodos que podem orientar os cuidados com os pacientes submetidos a procedimentos associados com distúrbios neurológicos. Este artigo descreve dois casos de pacientes submetidos à cirurgia cardiovascular com circulação extracorpórea, para os quais os procedimentos de neuroproteção na fase pós-operatória foram guiados pelos achados relacionados ao formato das ondas de pressão intracraniana, obtidos por meio de um método não invasivo de monitoramento.


ABSTRACT Brain injury caused by extracorporeal circulation during cardiovascular surgical procedures has been a recurring complication since the implementation of extracorporeal circulation five decades ago. There is no unique cause of brain injury due to the use of extracorporeal circulation, but it is known that brain injury affects about 70% of patients who undergo this procedure. Intracranial pressure assessment is one method that can guide the management of patients undergoing procedures associated with neurological disturbances. This study describes two cases of patients who underwent cardiovascular surgery with extracorporeal circulation in whom clinical protocols for neuroprotection in the postoperative phase were guided by intracranial pressure waveform findings obtained with a novel noninvasive intracranial pressure monitoring method.


Subject(s)
Humans , Intracranial Pressure , Cardiac Surgical Procedures/adverse effects , Extracorporeal Circulation , Neuroprotection , Intensive Care Units
7.
Rev. bras. cir. cardiovasc ; 36(3): 323-330, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1288251

ABSTRACT

Abstract Introduction: Our objective was to identify preoperative risk factors and to develop and validate a risk-prediction model for the need for blood (erythrocyte concentrate [EC]) transfusion during extracorporeal circulation (ECC) in patients undergoing coronary artery bypass grafting (CABG). Methods: This is a retrospective observational study including 530 consecutive patients who underwent isolated on-pump CABG at our Centre over a full two-year period. The risk model was developed and validated by logistic regression and bootstrap analysis. Discrimination and calibration were assessed using the area under the receiver operating characteristic curve (AUC) and the Hosmer-Lemeshow (H-L) test, respectively. Results: EC transfusion during ECC was required in 91 patients (17.2%). Of these, the majority were transfused with one (54.9%) or two (41.8%) EC units. The final model covariates (reported as odds ratios; 95% confidence interval) were age (1.07; 1.02-1.13), glomerular filtration rate (0.98; 0.96-1.00), body surface area (0.95; 0.92-0.98), peripheral vascular disease (3.03; 1.01-9.05), cerebrovascular disease (4.58; 1.29-16.18), and hematocrit (0.55; 0.48-0.63). The risk model developed has an excellent discriminatory power (AUC: 0,963). The results of the H-L test showed that the model predicts accurately both on average and across the ranges of deciles of risk. Conclusions: A risk-prediction model for EC transfusion during ECC was developed, which performed adequately in terms of discrimination, calibration, and stability over a wide spectrum of risk. It can be used as an instrument to provide accurate information about the need for EC transfusion during ECC, and as a valuable adjunct for local improvement of clinical practice. OR=odds ratio Key Question: What is the risk of the need for use of erythrocyte concentrate (EC) during cardiopulmonary bypass? Key Findings: Risk factors with the greatest prediction for EC transfusion. Take-Home Message: The implementation of this model would be an important step in optimizing and improving the quality of surgery.


Subject(s)
Humans , Cardiac Surgical Procedures , Blood Transfusion , Coronary Artery Bypass , Erythrocytes , Extracorporeal Circulation
8.
Rev. chil. cardiol ; 40(1): 11-19, abr. 2021. tab
Article in Spanish | LILACS | ID: biblio-1388073

ABSTRACT

Resumen: Antecedentes: El daño neurológico es una complicación devastadora de la cirugía con paro circulatorio del cayado aórtico y aorta ascendente. La perfusión anterógrada del encéfalo permite disminuir la incidencia de esta complicación, pero es un procedimiento engorroso que interfiere el campo quirúrgico. Para procedimientos más simples que requieran de paro circulatorio de menor duración, la Perfusión Cerebral Retrógrada (PCR) es una alternativa válida. Objetivo: Evaluar nuestros resultados en la cirugía del reemplazo total de la aorta ascendente tubular con paro circulatorio con hipotermia sistémica moderada y PCR. Material y Método: Entre enero de 2015 y enero de 2020 se identificaron los pacientes en la Base de Datos del Servicio de Cirugía Cardiaca de nuestra institución, se revisaron los protocolos operatorios, registros de perfusión y epicrisis, para obtener datos demográficos, clínicos y quirúrgicos pertinentes. La supervivencia alejada se certificó a través del "Servicio Registro Civil e Identificación de Chile". Resultados: En el periodo en estudio, 27 pacientes (21 hombres) tuvieron un reemplazo total de la aorta ascendente tubular con paro circulatorio con hipotermia moderada y PCR. Ocho pacientes tenían una cirugía previa; 7 de estos un reemplazo valvular aórtico. El 75% de los otros 20 pacientes tenía una válvula aórtica bicúspide. El diámetro máximo de la aorta ascendente fue en promedio 53,7 mm (45 a 67), y fue reemplazada en el 52% de los casos con un tubo protésico de 34 mm (promedio:32,4 mm; margen:30 a 34 mm). En 20 pacientes se efectuó un reemplazo valvular aórtico (15 con prótesis biológica). El tiempo promedio de circulación extracorpórea fue 174,6 min (97 a 243) y la temperatura sistémica mínima promedio fue 21ºC (18 a 25). El tiempo promedio de paro circulatorio fue 22,3 min (12 a 40) y de PCR 13 min (6 a 27). No hubo mortalidad operatoria. La morbilidad más frecuente fue la fibrilación auricular (33%). Una paciente presentó un episodio convulsivo aislado y otro fue reoperado por hemorragia postoperatoria. Una paciente falleció a los 48 meses de su operación. Conclusión: El paro circulatorio con hipotermia sistémica moderada y PCR para la cirugía de reemplazo total de la aorta ascendente facilitó la operación, con baja mortalidad y morbilidad en este grupo de pacientes.


Abstract: Background. Neurological damage is a devastating complication of aortic arch and ascending aorta surgery with deep hypothermic circulatory arrest. Antegrade cerebral perfusion significantly decreases the incidence of this complication, but it is a cumbersome procedure that interfere the surgical field. For more simple procedures, requiring a shorter period of circulatory arrest, retrograde cerebral perfusion (RCP) would be a valid alternative. Objective. To evaluate the results of total surgical replacement of the tubular ascending aorta with moderate hypothermic circulatory arrest and retrograde cerebral perfusion (RCP). Methods. Patients operated between January 2015 and January 2020 were included.Demographic, clinical and surgical information was obtained from the operatives notes, perfusion registry and discharge reports. Long-term survival was certified by the "Chilean Civil and Identification Registry". Results. 27 patients (21 men) underwent a total replacement of the tubular ascending aorta with circulatory arrest with moderate hypothermia and RCP. Eight patients had been previously operated on;7 of them had a previous aortic valve replacement. Of the remaining 20 patients, 75% had a bicuspid aortic valve. Average maximum diameter of the ascending aorta was 53.7 mm (45 - 67). Average size of the ascending aorta replacement graft was 32.4 mm (30 -34). In 20 patients a concomitant aortic valve replacement was performed (15 with a biological valve). Mean extracorporeal circulation time was 174.6 min (97 - 243) and mean minimal systemic temperature was 21ºC (18 - 25). Mean circulatory arrest time was 22.3 min (12 - 40) and mean RCP time was 13 min (6 - 27), There was no operative mortality. Atrial fibrillation was the most frequent post-operative morbidity (33%). One patient presented an isolated convulsive episode and another was re-operated due to postoperative hemorrhage. One patient died, 48 months after her operation. Conclusion. Moderate hypothermic circulatory arrest with RCP simplifies total tubular ascending aorta replacement, with low mortality and morbidity.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Perfusion/methods , Cerebrovascular Circulation , Circulatory Arrest, Deep Hypothermia Induced , Aneurysm, Ascending Aorta/surgery , Aortic Aneurysm/physiopathology , Postoperative Complications , Treatment Outcome , Extracorporeal Circulation , Heart Arrest, Induced , Hypothermia, Induced
9.
Rev. méd. Chile ; 149(2): 171-177, feb. 2021. ilus, tab, graf
Article in Spanish | LILACS | ID: biblio-1389438

ABSTRACT

Background: The number of patients waiting for a lung transplant worldwide greatly exceeds the number of available donors. Ex vivo lung perfusion is a useful tool that allows marginal donor lungs to be evaluated and reconditioned for a successful lung transplantation. Aim: To describe the first Chilean and Latin American experience in ex vivo lung perfusion for marginal donor lungs before transplantation. Material and Methods: Descriptive analysis of all ex vivo lung perfusion conducted for marginal donor lungs at a private clinic, from April 2019 to October 2020. High risk donor lungs and rejected lungs from other transplantation centers were included. The "Toronto Protocol" was used for ex vivo lung perfusion. Donor lung characteristics and recipient outcomes were studied. Results: During the study period, five ex vivo lung perfusions were performed. All lungs were reconditioned and transplanted. No complications were associated. There were no primary graft dysfunctions and only one chronic allograft dysfunction. There was no mortality during the first year. The median arterial oxygen partial pressure/fractional inspired oxygen ratio increased from 266 mm Hg in the donor lung to 419 after 3 hours of ex vivo lung perfusion (p = 0.043). Conclusions: ex vivo lung perfusion is a safe and useful tool that allows marginal donor lungs to be reconditioned and successfully transplanted.


Subject(s)
Humans , Lung Transplantation , Perfusion , Tissue Donors , Extracorporeal Circulation , Latin America , Lung/surgery
11.
Acta méd. costarric ; 62(4)dic. 2020.
Article in Spanish | LILACS, SaludCR | ID: biblio-1383342

ABSTRACT

Resumen Justificación: La mayor cantidad de cirugías cardiacas realizadas a nivel mundial se efectúa con circulación extracorpórea y pinzamiento de la aorta, lo que conlleva una serie de alteraciones fisiopatológicas que deben ser reconocidas por el personal de salud que participa en la atención de estos pacientes. Objetivo: Describir el perfil y los factores de riesgo presentes en los pacientes sometidos a cirugía cardiaca con circulación extracorpórea, y analizar la existencia de una potencial relación entre el tiempo de circulación extracorpórea y el pinzamiento aórtico, con la aplicación de desfibrilaciones tras al pinzado de la aorta, la necesidad de soporte cardiovascular farmacológico, el comportamiento del nivel de lactato plasmático y la mortalidad. Métodos: Se desarrolló un estudio observacional y descriptivo con una muestra de 104 pacientes electivos, sometidos a intervención quirúrgica y circulación extracorpórea, en el Hospital México, desde octubre de 2016 a noviembre de 2017. Se caracterizó la población en estudio, se analizaron los factores de riesgo incluido el EuroSCORE I y II, el tiempo de circulación extracorpórea, el tiempo de pinzamiento aórtico, las desfibrilaciones posteriores al pinzamiento aórtico, e lactato inmediatamente postcirculación extracorpórea, y a las 2, 6, 24 h postquirúrgicas, el uso de soporte cardiovascular farmacológico en infusión continua posterior a la circulación extracorpórea y mortalidad a los 30 días. Resultados: La edad media fue 56,4 años, predominó el sexo masculino (69 %) y la hipertensión arterial fue el factor de riesgo más frecuente (76,07 %). Se registró un tiempo de pinzado aórtico menor a 100 min en 61 pacientes (58,65 %) y superior a ese tiempo en 43 pacientes (41,35 %). El EuroSCORE I promedio fue del 4,21 % (DE: 4,80), mientras que el EuroSCORE II fue del 2,37 % (DE: 2,41). El tiempo promedio de circulación extracorpórea fue de 129 minutos (DE: 36,88) y el de pinzado aórtico, de 94 minutos (DE:32,04). Hubo un pico de lactato a las 6 horas postquirúrgicas (5,13 mmol/L, DE:2,89); un 8,65 % de los pacientes fueron desfibrilados después del retiro de la pinza en la aorta; se utilizó soporte cardiovascular en el 16,35 % y la mortalidad quirúrgica fue del 1,92 %. Conclusiones: En el estudio, el tiempo de circulación extracorpórea y el pinzado aórtico junto con el uso de inotrópicos, vasoconstrictores, hiperlactatemia y mortalidad quirúrgica, no alcanzó una relación significativa.


Abstract Justification: Currently, the largest number of cardiac surgeries performed worldwide are performed with cardiopulmonary bypass and aortic cross clamp, which leads to a series of pathophysiological alterations that are important for health personnel involved in the care of these patients. Objective: To describe the profile and risk factors present in patients undergoing cardiac surgery with cardiopulmonary bypass and the existence of a potential relationship between the cardiopulmonary bypass time and aortic cross clamping time, with the use of post clamp defibrillations, pharmacological cardiovascular support, plasma lactate behavior and mortality. Methods: An observational and descriptive study was carried out with a sample of 104 elective patients, undergoing surgical intervention and cardiopulmonary bypass at Hospital México, from October 2016 to November 2017. The study population was characterized, risk factors were analyzed including EuroSCORE I and II, CPB time, aortic cross clamping time, post-aortic clamping defibrillation, lactate immediately after extracorporeal circulation and at 2, 6, 24 hours postoperatively, use of pharmacological cardiovascular support in continuous infusion after extracorporeal circulation and mortality at 30 days. Results: The mean age was 56.4 years, the male sex predominated (69%) and arterial hypertension was the most frequent risk factor (76.07%). Aortic cross clamp time of less than 100 min was recorded in 61 patients (58.65%) and greater than that time in 43 patients (41.35%). The average EuroSCORE I was 4.21% (SD: 4.80), while the EuroSCORE II was 2.37% (SD: 2.41). The average cardiopulmonary bypass time was 129 minutes (SD: 36.88) and aortic cross clamp time was 94 minutes (SD: 32.04). There was a lactate peak at 6 postoperative hours (5.13 mmol/L, SD: 2.89); 8.65% of patients were defibrillated after removal the clamp in the aorta; pharmacological cardiovascular support was used in 16.35% and surgical mortality was 1.92%. Conclusions: In this study, cardiopulmonary bypass time and aortic cross clamp time together with the use of inotropics, vasoconstrictors, hyperlactatemia and surgical mortality did not reach a significant relationship.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Vasoconstrictor Agents , Extracorporeal Circulation/statistics & numerical data , Hyperlactatemia/diagnosis , Costa Rica
13.
Rev. peru. med. exp. salud publica ; 37(4): 672-680, oct.-dic. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1156833

ABSTRACT

RESUMEN Objetivo: Desarrollar un modelo de predicción de riesgo para infección posoperatoria mayor (IPM) a cirugía cardiaca pediátrica y validar el de la Society of Thoracic Surgeons (STS). Materiales y métodos: Se analizó una cohorte retrospectiva de 1025 niños sometidos a cirugía cardiaca con circulación extracorpórea (CEC) del 2000 al 2010. Se empleó un modelo de regresión logística y se validó el modelo. Resultados: De los 1025 pacientes, 59 (5,8%) tuvieron al menos un episodio de IPM (4,8% sepsis, 1% mediastinitis, 0% endocarditis). La mortalidad hospitalaria (63% vs. 13%; p<0,001), al igual que la duración de la ventilación posoperatoria (301,6 vs. 34,3 horas; p<0,001) y la estancia en la unidad de cuidados intensivos (20,9 vs. 5,1 días; p <0,001) fueron mayores en los pacientes con IPM. Los factores predictores fueron: edad, sexo, peso, cardiopatía cianótica, RACHS-1 3-4, clase funcional IV modificada por Ross, estancia hospitalaria previa y antecedente de ventilación mecánica. El modelo tuvo un c-estadístico de 0,80 (intervalo de confianza [IC] al 95%: 0,74-0,86) y es clínicamente útil. El modelo de la STS mostró un c-estadístico de 0,78 (IC 95%: 0,71-0,84) y Hosmer-Lemeshow de 18,2 (p = 0,020). Se realizó una comparación entre ambos modelos empleando una prueba exacta de Fisher. Conclusión: Se desarrolló un modelo para identificar preoperatoriamente a niños con alto riesgo de infección grave después de una cirugía cardiaca con CEC con buen desempeño y calibración. Asimismo, se validó el modelo de la STS con moderada discriminación.


ABSTRACT Objective: The aim of this study was to develop a risk prediction model for major postoperative infection (MPI) after pediatric heart surgery and to validate the model of the Society of Thoracic Surgeons (STS). Materials and methods: We analyzed a retrospective cohort of 1,025 children who underwent heart surgery with cardiopulmonary bypass (CPB) from 2000 to 2010. We used a logistic regression model, which was validated. Results: Of the 1,025 patients, 59 (5.8%) had at least one episode of MPI (4.8% had sepsis, 1% had mediastinitis, 0% had endocarditis). Hospital mortality (63% vs. 13%; p < 0.001), as well as duration of postoperative ventilation (301.6 vs. 34.3 hours; p < 0.001) and intensive care unit stay (20.9 vs. 5.1 days; p < 0.001) were higher in patients with MPI. The predictive factors found were age, sex, weight, cyanotic heart disease, RACHS-1 3-4, Ross-modified functional class IV, previous hospital stay, and previous history of mechanical ventilation. The proposed model had a c-statistic of 0.80 (95% CI: 0.74-0.86) and was considered as clinically useful. The STS model showed a c-statistic of 0.78 (95% CI: 0.71-0.84) and a Hosmer-Lemeshow of 18.2 (P = 0.020). A comparison between the two models was made using an accurate Fisher test. Conclusion: A model with good performance and calibration was developed to preoperatively identify children at high risk for severe infection after cardiac surgery with CPB. The STS model was also validated and was found to have a moderate discrimination performance.


Subject(s)
Humans , Male , Female , Thoracic Surgery , Cardiac Surgical Procedures , Infections , Postoperative Complications , Child Health , Extracorporeal Circulation , Forecasting
14.
Enferm. foco (Brasília) ; 11(2): 154-159, jul. 2020. graf, tab
Article in Portuguese | BDENF, LILACS | ID: biblio-1104412

ABSTRACT

Objetivo: traçar o perfil dos enfermeiros perfusionistas brasileiros atuantes no mercado de trabalho. Métodos: trata-se de um estudo observacional com delineamento transversal. Foram obtidos dados de perfil sócio demográfico e profissional dos perfusionistas em situação ativa no Brasil através do preenchimento de um questionário eletrônico. A amostra contemplou 70 enfermeiros perfusionistas. Resultados: a maioria dos profissionais é do sexo feminino (44%), possui 38,3±8,62 anos. A formação complementar demonstra um período de transição e aperfeiçoamento nesta especialidade: 84,2% destes possuem pós-graduação. Conclusão: o perfil profissional dos enfermeiros perfusionistas está em franca evolução em termos de qualificação e, nesse enfoque, torna-se necessário o conhecimento da especialidade para o delineamento de novas ações e inserção profissional em diferentes cenários da tecnologia extracorpórea. (AU)


Objective: to profile the Brazilian perfusionist nurses working in the labor market. Methods: This is an observational study with cross-sectional design. Data on socio-demographic and professional profile of perfusionists in active situation in Brazil were obtained by completing an electronic questionnaire. The sample included 70 perfusionist nurses. Results: most professionals are female (44%), 38.3 ± 8.62 years old. Complementary education demonstrates a period of transition and improvement in this specialty: 84.2% of these have postgraduate degrees. Conclusion: the professional profile of perfusionist nurses is clearly evolving in terms of qualification and, in this approach, it is necessary to know the specialty to delineate new actions and professional insertion in different scenarios of extracorporeal technology. (AU)


Objetivo: perfilar las enfermeras perfusionistas brasileñas que trabajan en el mercado laboral. Métodos: Este es un estudio observacional con diseño transversal. Los datos sobre el perfil sociodemográfico y profesional de perfusionistas en situación activa en Brasil se obtuvieron completando un cuestionario electrónico. La muestra incluyó 70 enfermeras perfusionistas. Resultados: la mayoría de los profesionales son mujeres (44%), 38.3 ± 8.62 años. La educación complementaria demuestra un período de transición y mejora en esta especialidad: 84,2% de ellos tienen títulos de posgrado. Conclusión: el perfil profesional de las enfermeras perfusionistas está evolucionando claramente en términos de calificación y, en este enfoque, es necesario conocer la especialidad para delinear nuevas acciones e inserción profesional en diferentes escenarios de tecnología extracorpórea. (AU)


Subject(s)
Extracorporeal Circulation , Cardiovascular Surgical Procedures , Nursing , Nurses
16.
Int. j. cardiovasc. sci. (Impr.) ; 33(3): 235-242, May-June 2020. tab
Article in English | LILACS | ID: biblio-1134372

ABSTRACT

Abstract Background: Heparin decreases the risks of thrombotic phenomena in extracorporeal circulation. However, it must present a robust safety profile itself, especially for bleeding. Contamination of porcine heparin demands an alternative source and consequent assessment of safety. Objective: To evaluate the safety of unfractionated bovine heparin during on-pump cardiac surgery. Methods: Descriptive, retrospective study, evaluating medical records from all patients who had on-pump cardiac surgery over four years. We observed the occurrence of bleeding, thrombocytopenia, postoperative vasoplegia, activated clotting time values and any other coagulation phenomena as safety profile parameters. Results: We evaluated 204 medical records reporting the use of unfractionated bovine heparin. 66.18% of the patients presented thrombocytopenia, 1.04% presented bleeding of more than 2000 mL in the first 24 hours of the postoperative period. One patient presented clots in the surgical field. Median activated clotting time was 137 seconds at baseline, 803 seconds after the first dose of heparin and, after protamine, it returns to similar baseline values, that is, 149.5 seconds. Conclusion: Unfractionated bovine heparin did not present unusual adverse effects and can be considered safe for on-pump cardiac surgery.


Subject(s)
Humans , Animals , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Cattle , Young Adult , Heparin/therapeutic use , Extracorporeal Circulation , Cardiac Surgical Procedures , Postoperative Period , Thrombocytopenia , Blood Coagulation Tests , Heparin/adverse effects , Epidemiology, Descriptive , Retrospective Studies , Postoperative Hemorrhage , Vasoplegia
17.
Rev. chil. cardiol ; 39(1): 16-23, abr. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1115445

ABSTRACT

ANTECEDENTES: El reemplazo protésico de la válvula tricúspide es un procedimiento infrecuente, con elevada mortalidad y morbilidad operatoria, independientemente de la etiología de la insuficiencia tricuspídea. Persiste aún una discusión respecto al tipo de prótesis a utilizar, mecánica o biológica. OBJETIVO: Analizar nuestros resultados perioperatorios y alejados en el reemplazo valvular tricuspídeo, comparando ambos tipos de prótesis. MÉTODO: Revisión de la Base de Datos de nuestro Servicio de Cirugía Cardiovascular para el periodo enero 1991 - diciembre 2017. Identificados los pacientes con reemplazo valvular tricuspídeo (RVT); se revisaron los protocolos operatorios y los ecocardiogramas. La supervivencia se certificó a través del Registro Civil e Identificación de Chile. RESULTADOS: Se identificaron 83 pacientes con RVT (76% mujeres), los que representaron el 0,7% del total de las cirugías con circulación extracorpórea y el 2,1% de las cirugías valvulares para el periodo en estudio. La edad promedio fue 49±16,5 años. Cuarenta y nueve casos (59%) correspondieron a reoperaciones y otros 49 tuvieron un procedimiento asociado. En 40 pacientes (48%) se utilizó una prótesis mecánica y en 43 (52%) una biológica. La mortalidad operatoria global fue 9,6% (8 pacientes, 4 con una prótesis mecánica y 4 con una biológica). El seguimiento se completó en el 100%, con un promedio de 7,1 años. Veintiocho pacientes fallecieron durante el seguimiento; la principal causa fue insuficiencia cardiaca. Así, la supervivencia a 5 años fue 70,3 ± 5,3% y a 10 años 58 ± 6,3%, sin diferencia significativa entre ambos tipos de prótesis. Siete pacientes se reoperaron durante el seguimiento (5 casos con prótesis biológica y 2 mecánica). CONCLUSIÓN: El RVT continúa siendo un procedimiento infrecuente, con mayor incidencia en mujeres, en la quinta década de la vida. La mayoría de los pacientes presentaba comorbilidad y había tenido cirugía cardiovascular previa. La mitad de estos recibió una prótesis mecánica y la otra, biológica. No hubo diferencias significativas entre ambos tipos de prótesis en cuanto a mortalidad operatoria, supervivencia alejada o reoperación.


BACKGROUND: Tricuspid valve replacement (TVR) is an uncommon surgical procedure, associated with high mortality and morbidity. The use of biological or mechanical prostheses in TVR has advantages and disadvantages and, therefore, there persists a debate regarding the choice of one or other type of prostheses. AIM: To analyze our operative and long-term surgical results, comparing both types of prosthetic valves. METHODS: The Data Base of the Cardiovascular Surgery Service was reviewed for the period between January 1991 and December 2017. 83 patients with TVR were identified, the operative notes and echocardiogram reports were analyzed. Survival was obtained from the Chilean Civil Identification Service. RESULTS: 83 patients (76% women) had TVR. They represented 0.7% of the total cases operated on with extracorporeal circulation and 2.1% of all valve disease cases, for the study period. Mean age was 49±16.5 years. 49 cases (59%) were reoperations and another 49 had an associated procedure. In 40 patients (48%) a mechanical prosthesis was used and in 43 (52%) a biological one was implanted. Operative mortality rate was 9.6% (8 patients, had a mechanical valve and the other 8, a biological one). Follow-up was 100% completed, with an average of 7.1 years. 28 patients died during follow-up; the main cause of death was heart failure. Five-year survival rate was 70.3 ± 5.3% and at 10 years it was 58 ± 6.3%, without significant difference the type of prostheses. Seven patients were re-operated during follow-up (5 cases corresponded to a biological prostheses and 2 to a mechanical one). CONCLUSION: TVR is still an infrequent surgical procedure, more commonly performed in women, on the fifth decade of life. Most patients presented comorbidities and had a previous cardiovascular surgical operation. Half of them received a mechanical prosthesis and half a biological one. There was no significant difference between both types of prostheses related to surgical mortality, long-term survival or reoperation.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Extracorporeal Circulation , Reoperation , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/mortality , Bioprosthesis , Comorbidity , Survival Analysis , Follow-Up Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/statistics & numerical data
18.
Rev. latinoam. enferm. (Online) ; 28: e3337, 2020. tab
Article in English | BDENF, LILACS | ID: biblio-1126989

ABSTRACT

Objective: to determine the microbiological characteristics of the red blood cells obtained with the cell saver in heart surgery patients on an extra-body circuit. Method: a cross-sectional and descriptive study conducted with 358 patients scheduled for heart surgery where the saver was used. Sociodemographic variables were collected, as well as from the saver and of the microbial identification in the re-infusion bag proceeding from the cell saver. Informed consent performed. Results: of the 170 GRAM+ bacteria isolations, the most frequent species were Staphylococcus epidermidis in 69% (n=138) of the cases and Streptococcus sanguinis with a report of 10% (n=20). Significant differences were found in the Staphylococcus epidermidis strain in patients with a Body Mass Index ≥25 (p=0.002) submitted to valve surgery (p=0.001). Vancomycin was the antimicrobial which resisted the Staphylococcus epidermidis strain with a minimum inhibitory concentration of >16 µg/ml. Conclusion: the microbiological characteristics of the red blood cells obtained after processing autologic blood recovered with the cell saver during heart surgery are of GRAM+ bacterial origin, the most isolated species being Staphylococcus epidermidis. Consequently, in order to reduce the presence of these GRAM+ cocci, an antibiotic should be added to the cell saver reservoir, according to a previously established protocol.


Objetivo: determinar as características microbiológicas dos glóbulos vermelhos obtidos com o "cell saver" em pacientes submetidos à cirurgia cardíaca em circuito extracorpóreo. Método: estudo descritivo transversal com 358 pacientes de cirurgia cardíaca em que o "cell saver" foi utilizado. Foram coletadas variáveis sociodemográficas e identificação microbiana da bolsa de reinfusão do "cell saver". Foi confirmado o Termo de Consentimento. Resultados: das 170 baterias isoladas GRAM+, as mais frequentes foram Staphylococcus epidermidis em 69% (n=138) dos casos e Streptococcus sanguinis com um registro de 10% (n=20). Diferenças significativas foram encontradas na cepa Staphylococcus epidermidis em pacientes com índice de massa corporal ≥25 (p=0,002) submetidos a cirurgia valvular (p=0,001). A vancomicina foi o antimicrobiano resistente à cepa Staphylococcus epidermidis com uma concentração inibitória mínima >16 µg/ml. Conclusão: as características microbiológicas dos glóbulos vermelhos obtidas após o processamento do sangue autólogo recuperado com o "cell saver" em cirurgia cardíaca são de origem bacteriana GRAM+, sendo a espécie mais isolada o Staphylococcus epidermidis. Portanto, para reduzir a presença desses cocos GRAM+, um antibiótico deve ser adicionado ao "cell saver", de acordo com um protocolo previamente estabelecido.


Objetivo: determinar las características microbiológicas de los glóbulos rojos obtenidos con el "cell saver" en el paciente de cirugía cardíaca bajo un circuito extracorpóreo. Método: estudio descriptivo transversal con 358 pacientes programados para cirugía cardíaca donde se utilizó el "cell saver". Se recogieron variables sociodemográficas e identificación microbiana de la bolsa de reinfusión procedente del "cell saver". Consentimiento informado realizado. Resultados: de 170 aislamientos de bacterias GRAM+, las especies más frecuentes fueron el Staphylococcus epidermidis en el 69% (n=138) de los casos y el Streptococcus sanguinis con un reporte del 10% (n=20). Se encontraron diferencias significativas en la cepa Staphylococcus epidermidis en pacientes con índice de masa corporal ≥25 (p=0,002) sometidos a cirugía valvular (p=0,001). La vancomicina fue el antimicrobiano resistente a la cepa Staphylococcus epidermidis con una concentración mínima inhibitoria >16 ug/ml. Conclusión: las características microbiológicas de los glóbulos rojos obtenidos tras el procesamiento de sangre autóloga recuperada con el "cell saver" en cirugía cardíaca son de origen bacteriano GRAM+ siendo la especie más aislada el Staphylococcus epidermidis. Por ello, con el fin de reducir la presencia de estos cocos GRAM+ se debería añadir un antibiótico en el reservorio del "cell saver", según un protocolo previamente establecido.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Operating Room Nursing , Staphylococcus epidermidis , Thoracic Surgery , Blood Transfusion, Autologous , Microbial Sensitivity Tests , Bacteremia , Erythrocytes , Extracorporeal Circulation , Anti-Bacterial Agents
19.
Rev. argent. cir ; 111(4): 274-283, dic. 2019. ilus, tab
Article in Spanish | LILACS | ID: biblio-1057370

ABSTRACT

Los aneurismas del cayado aórtico representan un desafío, ya que el involucramiento de sus grandes ramas exige una técnica quirúrgica compleja. A partir de la aparición del tratamiento endovascular, una alternativa desarrollada en los últimos años para abordar el cayado aórtico consistió en el tratamiento híbrido de esta patología, mediante la derivación quirúrgica de los vasos del cuello y la posterior exclusión del aneurisma con una endoprótesis. Este método híbrido es conocido con el nombre de debranching, y en forma simplificada consiste en realizar, sin circulación extracorpórea, una serie de puentes entre la aorta ascendente y el tronco braquiocefálico, la arteria carótida izquierda y eventualmente la arteria subclavia izquierda, para permitir avanzar una endoprótesis que cubra toda la luz del aneurisma. Se describe la técnica quirúrgica del debranching híbrido tipo I, sin el auxilio de la circulación extracorpórea e implante anterógrado de la endoprótesis, para los aneurismas del cayado aórtico.


Aortic arch aneurysms represent a major challenge as the involvement of the supra-aortic vessels demands a complex surgical technique. Since the advent of endovascular aortic repair, hybrid treatment of aortic arch disease has emerged in recent years. The procedure consists of surgical bypass of the supra-aortic vessels followed by exclusion of the aneurysm with an endograft. This hybrid method is known as debranching and, briefly, consists in performing bypasses between the ascending aorta and the brachiocephalic artery, the left carotid artery and possibly the left subclavian artery without cardiopulmonary bypass, in order to advance an endograft to cover the entire lumen of the aneurysm. The aim of this paper is to describe the surgical technique of type I hybrid debranching without cardiopulmonary bypass and antegrade endograft delivery to treat aortic arch aneurysms.


Subject(s)
Humans , Aorta , Aorta, Thoracic/surgery , Extracorporeal Circulation/methods , Endovascular Procedures/methods , Methods , Aorta, Thoracic , Arteries , Referral and Consultation , Relief Work , Subclavian Artery , Therapeutics , Cardiopulmonary Bypass , Disease , Brachiocephalic Trunk , Bridge , Extracorporeal Circulation , Aneurysm , Neck
20.
Rev. bras. cir. cardiovasc ; 34(6): 739-748, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1057500

ABSTRACT

Abstract Introduction: The true influence of the low mean arterial pressure (low MAP) during coronary artery bypass grafting (CABG) on the development of postoperative cognitive deficit (POCD) remains controversial. We aimed to perform a meta-analysis and meta-regression to determine the effect of low MAP on POCD, as well as moderator variables between low MAP and POCD. Methods: The Web of Science, PubMed database, Scopus and the Cochrane Library database (up to June 2018) were searched and retrieved articles systematically reviewed. Only randomized controlled trials (RCTs) comparing maintenance of low MAP (<80 mmHg) and high MAP (>80 mmHg) during cardiopulmonary bypass (CPB) were included in our final review. Statistical analysis of the risk ratio (RR) and corresponding 95% confidence interval (CI) was used to report the overall effect. The overall effect and meta-regression analysis were done using Mantel-Haenszel risk ratio (MHRR) and the corresponding 95% confidence interval (CI). Results: A total of 731 patients in three RCTs were included in this study. POCD occurred in 6.4% of all cases. Maintenance of low MAP did not reduce the occurrence of POCD (MHRR 1.012 [95% CI 0.277-3.688]; Z=0.018; P=0.986; I2=66%). Shorter CPB time reduced the occurrence of POCD regardless of group assignment (MH log risk ratio -0.519 [95% CI -0.949 - -0.089]; Z= -2.367; P=0.017). Conclusion: POCD is a common event among CABG patients. The neuroprotective effect of low MAP on POCD was attenuated by the prolonged CPB time.


Subject(s)
Humans , Male , Female , Postoperative Complications/prevention & control , Coronary Artery Bypass/rehabilitation , Cognition Disorders/prevention & control , Hypotension , Postoperative Complications/etiology , Postoperative Period , Coronary Artery Bypass/adverse effects , Risk Factors , Cognition Disorders/etiology , Extracorporeal Circulation , Arterial Pressure , Neuropsychological Tests